Vicpole EziFit pole
mounting system
|
|
Part No |
Pole Height |
Planting Depth (m)
|
|
VP EZIFIT 5.5 |
5.5m mounting height. |
1.4m |
|
VP EZIFIT 6.5 |
6.5m mounting height. |
1.5m |
|
VP EZIFIT 9.0 |
9.0m mounting height. |
1.7m |
|




|
|
Vicpole EZIFIT in-ground mounting base to suit all
installation applications up to 9.0m mounting height, meeting
Australian Standards.
FEATURES
•
The EziFit in-ground
base section was developed by Vicpole.
• Streamlines installation
process giving contractor control over timing of pole installation
and electrical connections. Foundation can be finished at the time
of cable laying, so paving and nature strips can be completed.
• Minimizes damage to pole
and light fitting during construction of the development.
•
Pole can be adjusted after erection insuring all poles are
installed straight.
• If
pole gets damaged it can be replaced without having to
remove in-ground section and cabling.
• If in-ground section has
any electrolysis damage after an extended period of time,
the in-ground section can be replaced and the lighting pole
re-used.
• EziFit base can be fitted
by trenching contractor who does not have to be the electrical
contractor.
• Can be ordered to fit
most styles of poles.
• Style of pole can be
determined at a later stage. If developer hasn’t decided on pole
design, the EziFit in-ground section can be fitted
early in the project preventing the contractor/development from
being "held up".
• Slotted base plate allows
rotation of pole to ensure alignment with road.
• EziFit base's are generally
ex-stock.
|
|
Foundation bolt mount
|
Part No |
Pole
Height |
Foundation
Bolt
mm
|
T
mm
|
D
mm
|
L
mm
|
E
mm
|
Bars
|
Ligatures
|
|
RBA16 |
3.0M |
16x550x350P.C.D.
|
16
|
610
|
1470
|
MIN
400
|
Y16
|
R6/500C/C
|
|
RBA16 |
4.0M |
16x550x350P.C.D.
|
16
|
610
|
1660
|
MIN
400
|
Y16
|
R6/500C/C
|
|
RBA20 |
5.0M |
20x550x350P.C.D.
|
20
|
762
|
1660
|
MIN
400
|
Y16
|
R6/600C/C
|
|
RBA20 |
6.0M |
20x550x350P.C.D.
|
20
|
762
|
1670
|
MIN
400
|
Y16
|
R6/600C/C
|
|
RBA20 |
8.0M |
20x550x350P.C.D.
|
20
|
762
|
1800
|
MIN
400
|
Y16
|
R6/600C/C
|
|
RBA20 |
9.0M |
20x550x350P.C.D.
|
25
|
762
|
1970
|
MIN
400
|
Y16
|
R6/600C/C
|
|
RBA24 |
10.0M |
24x550x350P.C.D.
|
25
|
762
|
1970
|
MIN
400
|
Y16
|
R6/600C/C
|
|
RBA24 |
12.0M |
24x550x350P.C.D.
|
25
|
762
|
2250
|
MIN
400
|
Y16
|
R8/600C/C
|
|
RBA24 |
15.0M |
30x850x466P.C.D.
|
32
|
762
|
2750
|
MIN
700
|
Y16
|
R8/600C/C
|
|
|
|
Note: Indicative footing detail based on terrain
Cat 2 and poor soil conditions.
Vicpole accepts no responsibility for footing details
given. All footing details are indicative only and footing sizes
will vary according to a number of factors, including soil
condition, wind loading and terrain categories. In all instances
it is the responsibility of the contractor to obtain engineers
computations to determine the footing detail required for each
site.
|
|
|
In-ground mount
click